FormalPara Key Summary Points

Diabetes technologies can help to improve health outcomes for individuals with type 1 diabetes (T1D) compared with traditional, self-injectable treatments.

However, many barriers remain to their use in Central and Eastern Europe (CEE), including lack of funding, underdeveloped health technology assessment (HTA) bodies and guidelines, unfamiliarity with novel therapies, and inadequacies in healthcare system capacities.

To overcome these barriers, the present position statement recommended the continued regional and national development of HTA bodies, more efficient allocation of resources, and structured education programs for healthcare professionals and people with diabetes.

The expert group wished to emphasize the responsibility of the healthcare community to ensure that all individuals with T1D gain timely access to modern, cost-effective technologies to improve health outcomes while providing value for money for healthcare payers.

The present position statement should be used to inform development of updated guidance in the CEE region for the reimbursement of efficacious diabetes technologies, including novel hybrid closed-loop systems.

Introduction

Type 1 diabetes (T1D) is a chronic autoimmune disease characterized by loss of pancreatic beta cells and subsequent insulin deficiency. Lifelong intensified insulin treatment is currently the only recommended treatment modality for T1D, with the aim to reduce hyperglycemia and thereby prevent diabetes-related complications and premature mortality. The disease is associated with a considerable clinical burden, with more than 46 million people affected worldwide and approximately 6 million people estimated to be living with T1D in Europe in 2019 [1]. Healthcare expenditure associated with T1D encompasses both therapy-related costs and treatment of diabetes-related complications, such as retinopathy, renal failure, neuropathy and foot ulceration, amputation, cardiovascular disease, and stroke, which arise from consistently heightened, uncontrolled blood glucose levels (measured via glycated hemoglobin [HbA1c]) and can influence the likelihood of premature mortality [2,3,4,5]. Diabetes-related complications can also have a substantial impact on the quality of life of people with diabetes (PwD) [6,7,8].

Ensuring consistent glycemic control with blood glucose levels within defined targets is crucial for reducing the incidence of complications, as shown by the landmark Diabetes Control and Complications Trial (DCCT) and the Epidemiology of Diabetes Interventions and Complications (EDIC) study [2,3,4, 9]. Optimal glucose control therefore remains the key goal of treatment for people with T1D. Improved time in range (TIR) of glycemic targets can also substantially reduce the stress and worry of PwD, thereby improving quality of life [10]. Barriers to efficacious diabetes technologies currently exist in many healthcare systems, which can prevent PwD from reaching glycemic control and thereby cause considerable harm to individuals over the long term, in terms of both health and psychological outcomes. Reimbursement of efficacious treatment options that improve glycemic control can also potentially lead to overall cost savings by reducing both short- and long-term diabetes-related complications and subsequent hospitalizations, medical procedures, and associated pharmacotherapy; indeed, improved glycemic control and absence of diabetes-related complications have been associated with reduced healthcare and societal costs [11, 12].

Treatment Modalities for Type 1 Diabetes

Precise insulin replacement therapy forms the cornerstone of T1D management, and there are many insulin treatment options and delivery methods available for PwD. Self-injection of multiple daily doses of insulin (MDI) represents the most common first-line therapy for people with T1D, with doses manually adjusted on the basis of planned or unplanned daily food intake, physical activity, and current blood glucose levels, which requires regular self-monitoring of blood glucose (SMBG) testing. While self-injection is an affordable insulin delivery mechanism, PwD need to be educated and trained appropriately in self-administration and should be confident enough to adapt doses to common daily activities. However, many individuals fail to consistently achieve target blood glucose levels, with an international study demonstrating that a large proportion of individuals do not achieve an HbA1c target of 7.0% (53 mmol/mol), and that approximately 68% of people with T1D were living with an HbA1c above 7.5% (58 mmol/mol) [13]. Hypoglycemia remains a common adverse effect of intensified insulin therapy, and fear of hypoglycemic events is a key factor in adherence to intensified insulin regimens [14,15,16]. Fear of hypoglycemia is compounded by hypoglycemia unawareness, defined as the onset of neuroglycopenia prior to symptoms or the failure to detect a significant drop below normal blood glucose levels [17]. Hypoglycemia unawareness is common in people with T1D, and can have a substantial impact on morbidity and mortality, with associated complications including bone fractures, joint dislocation, seizure, coma, cardiac arrhythmias, and an increased risk of severe hypoglycemia [18,19,20]. Both fear of hypoglycemia and hypoglycemia itself can have a substantial impact on quality of life and medical expenditure [21]. As perfect self-management is not a reality in most PwD, current T1D therapy is trending towards the broader use of technologies after initial treatment with MDI has proven ineffective (e.g., when not achieving glycemic targets, or experiencing pronounced dawn phenomenon, high glycemic variability, or problematic hypoglycemia).

The idea of a functional “artificial pancreas” was first conceived almost 50 years ago, and this closed-loop system arguably still represents the ultimate goal of treatments for people with T1D [22]. Advancements in diabetes technology have allowed for continuous monitoring of blood glucose and automated administration of insulin subcutaneously, leading to lower rates of and time spent in hypoglycemia and improved TIR. Indeed, real-world data have indicated that both adult and pediatric populations with T1D experienced improved glycemic control with modern diabetes technologies compared with MDI [23, 24]. However, many access barriers remain to their use, particularly in the Central and Eastern European region, where substantial healthcare funding for diabetes technologies is often absent.

Aim

The aim of this position statement was to summarize the available types of diabetes technologies and outline their clinical use cases, explore barriers to access for these technologies, and outline possible approaches to improving medical care for adult and pediatric populations with T1D in Central and Eastern Europe, as well as providing regional clinical recommendations for hybrid closed-loop (HCL) systems.

Compliance with Ethics Guidelines

This article is based on previously conducted studies and does not contain any studies with human participants or animals performed by any of the authors.

Diabetes Technologies and Their Applications

The current level of evidence and recommendations for use of modern diabetes technologies are summarized in Table 1.

Table 1 Recommendations for use of current diabetes technologies

Continuous Glucose Monitoring and Subcutaneous Insulin Infusion

Continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion (CSII) are two diabetes technologies that have revolutionized diabetes care, with both technologies associated with improved HbA1c levels, increased TIR, and fewer hypoglycemic events compared with MDI [23,24,25,26,27,28].

CGM is achieved through a compact medical device that monitors blood glucose levels in real time, which can send alerts to either a dedicated monitoring device or a smartphone app. CGM thereby reduces the need for frequent SMBG testing (and associated finger-pricking), and is frequently offered to PwD experiencing persistent hyper- or hypoglycemia [29]. The latest guidelines published by the Endocrine Society in the USA recommended use of CGM devices in adult populations with T1D who are willing to utilize the devices on a near-daily basis, irrespective of glycemic control status [30]. Moreover, a 2017 international consensus statement recommended the use of CGM, in combination with regular HbA1c measurements for glycemic status assessment and subsequent therapy adjustment, in all people with T1D not achieving glycemic targets, particularly when hypoglycemia is a concern [31]. It was indicated that all individuals should receive training on how to interpret and respond to glycemic data, with education utilizing standardized programs with follow-up to improve adherence and ensure appropriate use of data and therapies [31]. The consensus statement also recognized the importance of wearing CGM devices on a near-daily basis to optimize their benefits, and concluded that CGM should be considered to help improve glycemic control, provided that appropriate educational and technical support is available [31].

CSII is achieved through devices known as insulin pumps, which provide a readily available and steady administration of insulin subcutaneously, while also allowing the user to instantaneously administer insulin should the need arise to help control blood glucose levels. CSII also relieves the user of the majority of self-injections, thereby offering quality-of-life benefits [32]. Guidelines published by the Endocrine Society in 2018 recommended CSII use over MDI in populations with T1D who are capable of using the device and are not achieving glycemic control targets; are achieving targets but continuing to experience severe hypoglycemia or high glycemic variability; require increased flexibility with insulin administration or seek improved treatment satisfaction [30]. The Endocrine Society also recommended that, prior to CSII use, a structured evaluation should be performed assessing the individual’s psychological status, historical adherence patterns, willingness to use and interest in the device, and availability for follow-up consultations [30]. All adults using CSII were also indicated to receive sufficient education, training, and ongoing support to achieve and maintain glycemic targets [30]. A position statement from the American Diabetes Association (ADA) indicated that viable candidates for CSII must be strongly motivated to improve glycemic control, and be willing to work in tandem with their healthcare professional to achieve treatment targets [33]. In addition, individuals must be appropriately trained to use the pump, perform SMBG testing, and interpret the measured data. Similar to the position statement for CGM, use of CSII was recommended alongside thorough education of PwD by skilled professionals [33]. However, the ADA acknowledged that physicians’ opinions can vary when prescribing CSII, with some recommending pump therapy for motivated PwD with daily schedules unsuited to MDI, and others only endorsing prescription when treatment with MDI fails to achieve glycemic control [33]. A further consensus statement published in 2021 by the American Association of Clinical Endocrinologists/American College of Endocrinology (AACE/ACE) indicated that CSII should only be provided if the prescribing practice can offer a comprehensive pump management program for PwD [34]. Moreover, the AACE/ACE emphasized appropriate patient selection with a thorough assessment of the individual’s knowledge of diabetes management principles [34]. Combination of these guidelines and position statements indicate the ideal CSII candidate as an individual with T1D currently performing four or more insulin injections and SMBG tests per day, who is motivated to achieve optimal glycemic control, and is willing and able to carry out the tasks associated with CSII safely and effectively, while maintaining frequent contact with their healthcare team [30, 34, 35].

Sensor-Augmented and Sensor-Integrated Pumps

Sensor-augmented pumps (SAPs) and sensor-integrated pumps (SIPs) combine CGM with CSII to form highly efficacious therapies. SAPs and SIPs differ in their response to CGM data: SAPs display CGM data and require the user to manually program their insulin pump, while SIPs integrate low-glucose suspend (LGS) or predictive LGS functions to automatically take action in response to CGM data (e.g., when blood glucose levels drop below or are predicted to drop below set targets) [36]. Published evidence has indicated that SAPs are associated with reduced moderate and severe hypoglycemia compared with MDI and reduced severe hypoglycemia compared with CSII, as well as improved blood glucose levels and glycemic variability versus sensor-augmented MDI therapy, while SIPs have been associated with a significantly reduced time spent in hypoglycemia and substantially fewer non-severe and severe hypoglycemic events compared with CSII in individuals with T1D with a high risk of hypoglycemia [37,38,39]. SIPs have also been associated with effective prevention of exercise-induced hypoglycemia [40, 41].

Hybrid Closed-Loop Systems

Novel hybrid closed-loop (HCL) systems represent advanced diabetes technology that provide automated insulin delivery driven by algorithms, which can respond automatically to changes in blood glucose levels and administer basal and correction bolus insulin doses appropriately. Users must provide regular meal announcements and the corresponding carbohydrate intake to the device, but otherwise HCL systems have the potential to improve blood glucose control and reduce the risk of hypoglycemia compared with MDI, CSII, or non-automated SAP therapy. Moreover, HCL systems can decrease the self-management burden of T1D compared with other treatment modalities.

Predictive low-glucose management (PLGM) functions, a precursor to HCL systems, were associated with reduced diurnal and nocturnal hypoglycemia and significantly fewer hypoglycemic events in children and adolescents in a long-term randomized controlled trial published in 2018, as well as significantly improved TIR in a 2018 randomized crossover study, with participants noting that using the automated system was associated with less time thinking about diabetes, decreased worry about blood glucose levels, and decreased burden in managing diabetes [42, 43]. HCL systems have been associated with significantly fewer hypoglycemic events and improved TIR compared with typical pump therapy with or without LGS [44,45,46]. HbA1c levels in both adolescents and adults have also been shown to significantly improve after 3 months on a first-generation HCL system, with significantly improved TIR compared with the device’s manual mode [47]. Data from a 2019 randomized controlled trial indicated that TIR with HCL was higher versus the manual SAP mode after 6 months (61% at baseline to 71% with HCL, versus unchanged at 59% in the manual SAP group [mean adjusted difference 11 percentage points; 95% confidence interval 9–14]; p < 0.001) [48]. Furthermore, preliminary data from a pivotal trial of an advanced HCL system in the USA have indicated no severe hypoglycemia or diabetic ketoacidosis with the novel device, as well as improved HbA1c levels (72% of individuals reaching an HbA1c of 7.0% [53 mmol/mol] after 90 days, compared with 52% at baseline, increasing to 84% with optimal system settings) and TIR (69% of individuals reaching a TIR target of 70%, compared with 45% at baseline, increasing to 79% with optimal system settings) [49]. The rate of users reported to utilize the closed-loop functionality of the device was 95% [49]. Improved glycemic control, general well-being and sleep, as well as a reduced burden of diabetes and visible real-time glucose data have been identified as positive key elements in a recent study evaluating closed-loop versus SAP technology [50].

Diabetes Technology Use in Central and Eastern Europe

HCL systems represent the most advanced and the most effective form of insulin delivery currently available for people with T1D. However, novel diabetes technologies are often underutilized, particularly in Central and Eastern Europe (Figs. 1 and 2). The estimated uptake of insulin pump technology in T1D was 6.9% in Eastern Europe in 2018, and is not homogeneous across countries despite similar levels of healthcare expenditure (data on file). CGM uptake is also hindered by its high cost, as well as issues that remain even in modern systems: the need for regular sensor replacement as well as initial and regularly performed calibrations through SMBG testing [51].

Fig. 1
figure 1

Levels of reimbursement for CSII in Central and Eastern Europe

Fig. 2
figure 2

Levels of reimbursement for SAP in Central and Eastern Europe

A recent study reported the highest global rate of unconfirmed symptomatic hypoglycemia in people with T1D in Central and Eastern Europe, indicative of the underutilization of more advanced treatment options for T1D in this region [52]. Accordingly, large registry studies have demonstrated that low use of technology is associated with inadequate glycemic control and higher HbA1c levels [53, 54]. Wider use of diabetes technologies, including HCL systems, would provide clear glycemic control benefits for people with T1D, while decreasing the self-management burden with automated insulin delivery. However, current reimbursement criteria are not homogenous across Central and Eastern European countries, and numerous barriers to access exist for diabetes technology in the region that must be addressed to achieve more consistent and equal technology uptake.

Current Reimbursement in Central and Eastern Europe

Guidelines for the reimbursement of CSII and SAP therapies in ten Central and Eastern European countries (Bulgaria, Croatia, Czechia, Hungary, Poland, Romania, Serbia, Slovakia, Slovenia, and Ukraine) were evaluated, based on country-specific national health insurance fund data [55,56,57,58,59,60,61,62,63,64,65,66].

CSII Reimbursement

Reimbursement of CSII was reported in Czechia, Romania, Serbia, Slovakia, and Slovenia, while limited reimbursement (supplemented with co-pay) was reported in Bulgaria and Poland (Fig. 1 and Table 2). In Croatia, reimbursement was covered by a national tender but with limited quantities of devices—individuals can otherwise cover the complete cost out-of-pocket. In Hungary, reimbursement was reported only in individuals aged less than 18 years and only in special cases in individuals aged between 18 and 21 years, with a co-pay of 20% required in most cases for individuals aged 18 years or more. Ukraine was found to have no current reimbursement criteria for medical devices, with potential health technology assessment (HTA) guidelines under discussion.

Table 2 Reimbursement criteria for CSII in Central and Eastern Europe

Population criteria for reimbursement were similar across countries, encompassing both children and adults with T1D experiencing inadequate glycemic control and/or hypoglycemia. Poland restricts reimbursement to individuals with T1D aged at most 26 years and Ukraine limits prescription on a case-by-case basis in pediatric populations, but Bulgaria, Croatia, Czechia, Hungary, Romania, Serbia, Slovakia, and Slovenia have no age limits for reimbursement. Interestingly, despite similar population indications across the countries, varying levels of estimated insulin pump uptake are reported in the Central and Eastern European region (data on file).

SAP Reimbursement

Reimbursement of SAP (CSII plus CGM) was reported in Croatia, Serbia, Romania, and Slovenia, with limited reimbursement (supplemented with co-pay) reported in Bulgaria, Hungary, Poland, and Slovakia (Fig. 2 and Table 3). Czechia was found to provide reimbursement of the insulin pump, but had an annual limited budget (supplemented with co-pay) for the sensor technology; novel HCL systems could therefore be reimbursed in Czechia under the current guidelines, should the price of the device fall within the annual budget. No specific reimbursement recommendations were found for Ukraine, with an HTA framework for medical devices under discussion.

Table 3 Reimbursement criteria for SAP in Central and Eastern Europe

Population indications for countries endorsing reimbursement varied. In Croatia, up to 40 sensors (plus one transmitter) per year are reimbursed for the SAP system in all individuals with T1D with existing insulin pumps and HbA1c levels greater than 7.5% (58 mmol/mol). In Serbia, SAP reimbursement is limited to one of the following: PwD on MDI with three consecutive HbA1c measurements greater than 8.5% (69 mmol/mol) in routine appointments; PwD on MDI with diabetic kidney disease with two consecutive HbA1c measurements greater than 7.5% (58 mmol/mol); or pregnant individuals with two consecutive HbA1c measurements greater than 7.0% (53 mmol/mol). However, individuals with T1D receiving CSII therapy are eligible for up to 52 sensors and one transmitter per year in Serbia, irrespective of other criteria. In Slovenia, there are no restrictions on SAP reimbursement, with the primary indication being HbA1c and TIR targets, along with persistent hypoglycemia [31]. In countries with partial reimbursement, population indications were comparable, with fixed reimbursable amounts set by national healthcare authorities and co-pay above these thresholds.

The lack of uptake and indifference to novel diabetes technologies are evidenced by these reimbursement criteria, with CSII reimbursed in six countries, but SAP reimbursed in only four countries. The panel aimed to assess the potential barriers to reimbursement and use of diabetes technologies, and provide solutions to potentially avoid similar lack of uptake of novel HCL systems, given the clinical benefits that these devices offer [42, 43, 47,48,49].

Barriers to Technology Use in Type 1 Diabetes

The panel discussed several key barriers to technology use in the Central and Eastern European region, which can be broken down into several categories (Table 4).

Table 4 Potential barriers and solutions to diabetes technology use

Access and Funding

A key issue in Central and Eastern European countries is the lack of funding for novel medical devices, with available public resources more limited compared with Western European countries [67, 68]. This is particularly pertinent for treatments for T1D—funding may not be present for novel technologies when the more affordable MDI therapy is the alternative, and when short-term financial drivers override long-term health economic benefits. While lack of funding represents the major problem in the region, nascent HTA agencies are also a hindrance in some Central and Eastern European countries, such as Romania and Ukraine—these agencies have less health economic expertise to draw from than their Western European counterparts, which have long-running and experienced HTA bodies in place [such as the National Institute for Health and Care Excellence (NICE) in England, the Haute Autorité de santé (HAS) in France, and the Institut für Qualität und Wirtschaftlichkeit im Gesundheitswesen (IQWiG) in Germany] [69,70,71,72]. Outdated and non-evidence-based eligibility criteria for novel therapies can prevent PwD receiving new, efficacious technologies, particularly if funding is instead diverted to medications at high prices with limited health gains [73,74,75,76]. It has been suggested that HTA implementation in the Central and Eastern European region be particularly resource-conscious, with transferability of evidence (e.g., clinical evidence, HTA methodology, and policy) between countries in the region emphasized wherever possible [77]. However, the aspects of HTA that are transferable between countries should be carefully considered, given that each country faces its own unique challenges and comprises different populations.

Lack of resources and funding also influences the level of education both physicians and PwD have access to, which can limit knowledge of diabetes technologies and hinder uptake. Fewer resources and less funding can lead to fewer diabetes-specific treatment clinics and less specialized care, particularly in rural areas [78, 79].

Human Factors

Human factors include perceptions, beliefs, attitudes, expectations, and preferences for treatment modalities for T1D. Lack of awareness of available therapies for both physicians and PwD, stemming from insufficient education on diabetes technologies, can limit the treatment options that can be prescribed and lead to apathy in achieving treatment targets. Fear and experience of hypoglycemia, a common side effect of MDI therapy, can also limit adherence to treatments and cause therapeutic inertia and subsequent inadequate glycemic control [14,15,16]. Fear of these events continuing or worsening on novel technologies, the benefits of which can be largely unknown to PwD, could also drive lack of uptake. A high level of knowledge and education has been identified as a key factor behind treatment adherence and maintained glycemic control in numerous studies, and indifference in achieving treatment targets can lead to acceptance of inefficacious treatments, inadequate glycemic control, and an increased clinical and economic burden on healthcare systems [80].

Differences between adult and pediatric populations with T1D should also be noted. Countries such as Poland and Hungary have age limits on reimbursement criteria, and PwD can therefore lose access to technologies as they age. It is perhaps a misconception that older PwD may be less willing to adopt and learn how to use novel technologies; data have shown a willingness to do so, provided enough support is offered [81]. Indeed, some younger PwD have been associated with less use of diabetes technologies due to an aversion of wearing the devices [82].

Healthcare System Capacity Limitations

Tied to the lack of overall resources in the Central and Eastern European region, the physical capacity of clinics to deal with structured education of physicians and PwD is a potential issue. Moreover, the number of adequately trained and knowledgeable physicians who can effectively inform PwD of the available treatment options (and how to use technologies such as CSII and SAP) is suboptimal. In Czechia in 2018, data on file indicated 581 care providers and a calculated estimate of 480 full-time diabetologists working in specialized diabetes departments, while in Slovakia, the total number of diabetologists was estimated to be 285, meaning one diabetologist was caring for approximately 1200 PwD [83]. The number of diabetologists in the region varies from country to country, but similar patterns emerge: an estimated 36 (13 for pediatric populations) specialized diabetology pump centers in Hungary; a total of 1929 endocrinologists for the diabetic population (and 185 pediatric endocrinologists for 10,743 children with diabetes) in Ukraine; approximately 1500 diabetologists in Romania; and 1300 specialists in Poland, where approximately 1500 are required for the population size [79]. In these cases, diabetes care must be provided by general practitioners, who may or may not be educated enough to provide informed decisions and technology training for PwD.

Steps Towards Optimizing Technology Use in Type 1 Diabetes

Advanced technologies can provide numerous clinical benefits for individuals with T1D, and yet their use remains limited, particularly in Central and Eastern Europe. On the basis of the barriers to uptake discussed in the present paper, the panel recommends application of basic, evidence-based, regional guidelines for the use of technology in the treatment of T1D that can be applied locally according to the specific requirements and abilities of each country. These should incorporate structured education of physicians and PwD to increase the knowledge of potential treatment options and improve skills in using advanced devices, thereby improving efficiency and driving uptake.

Overcoming the Access and Funding Barriers

Improvement or creation, implementation, and development of HTA bodies in Central and Eastern European countries should help to drive more understanding of long-term cost-effectiveness, overcome the focus on short-term cost outcomes, and establish health economic analyses as the basis for reimbursement decisions for any novel medical intervention [84]. In turn, this approach could enable better allocation of limited funding resources towards interventions that promote greater overall health benefits for the population while providing value for money, and thereby increased funding for novel diabetes technologies, should they prove cost-effective. Indeed, a recent cost-effectiveness analysis in the UK showed that an advanced HCL system was associated with cost savings over PwD’s lifetimes owing to a reduced incidence of diabetes-related complications [85]. Procurement of biosimilar insulins could also help healthcare authorities in Central and Eastern Europe to save resources and allow funding to be redirected to novel diabetes technologies.

A recent study in Bulgaria has recommended the improvement of the HTA framework and collaboration between healthcare professionals and pharmaceutical structures to encourage a better understanding of diabetes technologies [86]. A focus on long-term analyses should also be particularly pertinent for diabetes interventions, as the majority of expenditure arises from long-term diabetes-related complications, and ADA modeling guidelines for diabetes interventions indicate a lifetime time horizon to capture all relevant clinical and cost outcomes [5, 87]. For novel HCL systems, provision of cost-effectiveness analyses to these existing or nascent HTA authorities can help overcome funding barriers. These analyses should demonstrate the clinical benefits of the intervention in terms of quality of life while providing value for money for the healthcare payer, and can follow similar cost-effectiveness analyses published for other country settings [85, 88, 89]. That acknowledged, short-term studies can still demonstrate utility evidenced by recent real-world data that indicated SAP therapy led to improved HbA1c and quality of life, and reduced fear of hypoglycemia, acute diabetes-related complications, and work absenteeism over both 12 and 24 months [90, 91].

Targeting older PwD by expanding the population indications for CSII in Poland and Ukraine (where age limits currently exist) could also increase use of diabetes technologies in populations that could benefit greatly from these devices. Older people with T1D experience an increased risk of severe hypoglycemia (due to a combination of factors including reduced awareness of hypoglycemic warning symptoms and increased response time) and are therefore viable candidates for CGM, SAP, and HCL systems. Expanding coverage of SAP to near full reimbursement for children with diabetes could also prove useful in Slovakia, with an increasing proportion of pediatric individuals diagnosed with T1D, meaning a substantial number of individuals will require almost lifelong treatment and management programs [92]. Moreover, expanding coverage of expert telemedicine to people with T1D living in rural areas could overcome barriers to care should development of nearby, dedicated diabetes centers prove untenable.

Overcoming the Human Barriers

Improvements in the presentation of novel diabetes technologies can help to overcome potential apathy towards management of T1D. Improving knowledge in PwD of the efficacy of these technologies, which can lower the risk of hypoglycemic events versus MDI, can drive reduced fear of hypoglycemia and subsequently improved adherence, better glycemic control, and improved quality of life [14,15,16, 21]. The improved user-friendliness of diabetes technologies should also be emphasized, as these benefits are likely to translate into more intensive usage and, consequently, lower HbA1c values [93]. That acknowledged, the attending physician must also be aware of these benefits so they can accurately inform PwD. Country-specific, round-table discussion sessions involving healthcare professionals, PwD, healthcare authorities, and state representatives could be arranged to identify the key hesitations to the use of diabetes technologies amongst physicians and PwD, and to better present the clinical benefits of these devices to allay any potential concerns. Moreover, data obtained from diabetes treatment can be analyzed and published to clearly demonstrate the benefits of technologies in real-world practice.

Improving the physical features and appeal of wearable diabetes technologies to younger PwD has been identified as a key factor in driving uptake in pediatric populations, but the panel felt that extolling the benefits of the systems in terms of improved glycemic control and a lower risk of hypoglycemia, as well as reduced burden of managing the disease, should be the focus in this population and that this could overcome other hesitations [78]. Support from peers (as well as advocacy of novel therapies) can also help drive uptake. In all populations, presentation of these technologies should be associated with a structured and standardized training program for people with T1D initiating technology therapy, with co-operation between the physician and patient key.

Overcoming the Healthcare Inefficiency Barriers

A structured and homogenous training program for physicians can help to standardize care throughout the Central and Eastern European region. Combined with increasing the number of specialized diabetologists in the region—through novel training courses, more mobile and regularly operating units in rural areas, and more direct contact between local governments and the International Diabetes Federation (IDF), which may be especially useful in countries with the poorest access to advanced diabetes care—this can lead to improved leadership and organization of departments, thereby driving efficiency in the provision of technological therapies. In turn, this can drive uptake in individuals with T1D as physicians become more knowledgeable of the technologies and their benefits and explain these to their patients. Diabetes teams can promote optimal utilization of devices and support problem solving with patients, helping to improve glycemic control, optimize quality of life, and reduce or prevent device discontinuation [94, 95].

Lessons from Prior Position Statements

A 2021 consensus statement indicated that characteristics of individuals with diabetes can be used to predict successful utilization of CSII [34]. For example, a preferred candidate for CSII would be an individual with high engagement with their diabetes regimen (i.e., highly motivated to achieve optimal blood glucose control yet unable to do so on current therapy). Conversely, individuals who are less motivated by technology, have a history of nonadherence to MDI protocols, or who report substantial reservations about pump usage interfering with lifestyle were not anticipated to be good candidates for CSII. However, psychological factors that can be externally influenced can play a large role in increasing or decreasing patient engagement and expectations; people recognizing that success or failure of therapies are attributable to their own efforts have been reported to engage more effectively with pump use [96]. These characteristics also apply for individuals eligible for HCL systems.

A 2017 international consensus statement recommended the use of CGM alongside a substantial education program, to ensure that individuals have the knowledge to interpret data and use devices appropriately [31]. This aligns with the panel’s recommendation of a structured training program on initiation of diabetes technologies, performed by an adequately trained and specialized healthcare professional.

A recent position statement covering several Central and Eastern European countries, including Croatia, Serbia, and Slovenia, indicated the ideal candidate for diabetes technologies as an educated individual with a full understanding of the principles of intensive insulin therapy, motivated to improve glycemic control, without reservations about pump therapy, and with a history of adherence and engagement with diabetes services. Parental supervision is advised for individuals with T1D aged less than 15 years, but CSII should be considered for all PwD who can safety manage the device. Individuals should also undergo periodic evaluation to ensure that CSII treatment is effective. CGM use was endorsed in all individuals with T1D using either CSII or MDI. Emphasis was given to a well-trained, multidisciplinary team for appropriate patient selection and education, via a comprehensive pump and sensor management program. Combination of CSII and CGM in SAP therapy was recommended in both pediatric and adult populations, particularly for individuals experiencing a high risk or fear of hypoglycemia, provided the benefits of the system correlate with adherence.

Recommendations for National and Regional Guidelines

The panel recommended use of HCL systems in individuals of all ages with T1D with any of the following criteria: diagnosis within the past 6–12 months; previous intensive insulin therapy combined with CGM over a period of 3–6 months; HbA1c values greater than 7.0% (53 mmol/mol); TIR less than 70%; clinically relevant or severe hypoglycemia with time below range (TBR) greater than 4.0%; or high glycemic variability. These minimal criteria formed the basis of the updated guidance in several Western countries and Slovenia (Table 3), and the panel expressed a desire to extrapolate these guidelines to the entire Central and Eastern European region.

Conclusions

The present position statement emphasizes the endeavor of the healthcare community to ensure that individuals with T1D gain access to efficacious technology in a timely and economically responsible manner, thereby improving key health outcomes such as glycemic control and quality of life. Lack of funding to Central and Eastern European healthcare programs was identified as a key barrier to access. Alongside improvements in funding and efficient reallocation of resources, structured education of physicians and PwD should form the basis of implementing diabetes technologies for T1D. Further development of HTA organizations in the region should also help to improve evidence-based reimbursement and implementation of cost-effective measures to improve health outcomes while maximizing healthcare resources and providing value for money for healthcare systems and society overall.